Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
JOURNAL OF RARE DISEASES ; (4): 135-142, 2023.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-1005055

RESUMO

Health security for rare diseases has aroused much attention in the society nowadays, In this article, we analyzed in-depth the construction of rare diseases health security in China by studying the literature reviews, expert interviews, and reports of pilot policy investigations. We conclude in the study that it is an important step to constructing a multiple health security system for the rare disease making the basic health security as the cornerstone. For rare medications and treatments that cannot be covered by the current national health insurance, it is necessary to build an specific funding for rare disease funding as a means of safeguard. Finally, for those who are financially disadvantages, the system should involve relief and philanthropy to help them. By constructing a multiple health security system, rare diseases patients in our country will get a well-covered health care.

2.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-617448

RESUMO

Objective To develop a method for the determination of five furostanol saponins(timosaponin N,timosaponin L, timosaponin BⅡ,25R-timosaponin BⅡ,and 25S-officinalisnin-Ⅰ)in rhizome and fibrous root of Anemarrhena asphodeloides Bge. by HPLC with the charged aerosol detector(CAD). Methods The analysis was performed on TechMate C18-ST-II(250 mm×4.6 mm,5μm)with acetonitrile:water(22:78,V/V),the flow rate of 1.0 ml/min and column temperature at 30℃. The Corona parameters were as follows:sampling rate 10 Hz,filter 5 s,and the nebulizer temperature 55℃. Results The approach showed good linearity for five saponins. The correlation coefficients(r2)for calibration curves varied from 0.9992 to 0.9998. The limits of detection(LOD)were 0.28,0.92,0.92,0.92 and 0.92 ng for five steroidal saponins,respectively. The limits of quantitation(LOQ)were found to be 0.92, 2.77,2.77,2.77 and 2.76 ng,respectively. RSD calculated from peak area of precision,repeatability and stability in 48 h were all less than 3.0%. The average recoveries of timosaponin N,timosaponin L,timosaponin BⅡ,25R-timosaponinBⅡ,and 25S-officinalis-nin-Ⅰwere 98.17%,101.37%,98.53%,97.63%,and 98.17%,respectively. Conclusion The developed method is accurate,reli-able,which could be applied to the quality control of multiple components in A. asphodeloides Bge.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...